Eltel Industries
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
Pulse Electronics
Our high-performance telecom transformers support multiple home phone line and power line network applications. These transformers have excellent THD performance, small footprints, and are designed to exceed industry standards. Single, dual, quad, six, octal and twelve transformer numbers are available.
-
Howard Butler Ltd.
A range of ring type current transformers suitable for primary currents from 1A-5000A with 1A or 5A secondaries. This standard range of measuring and protective current transformers is available as resin coated or tape wrapped.
-
IEC Burden Sets -
The Eastern Specialty Company
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
STDE -
Altanova Group
This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.
-
Shanghai Jiuzhi Electric Co., Ltd.
Our advanced power and distribution transformer test system and components are used for testing transformer up to 1000kV/600MVA. Samgor perform the following tests in accordance with ANSI / IEEE C57.12.90 and IEC 76 latest edition standards.
-
Osborne Transformer Corp.
Osborne’s Control Transformers are commonly used to step down primary circuit voltages to lower voltages to be used for control circuit applications. These units set the standard for premium, high performance, hand crafted control transformers. Your customers will appreciate your decision to work with the quality and reliability of Osborne Transformer’s control transformers.
-
Carl E. Holmes Company
CEHCO manufactures Transformer Rectifier Assemblies for Crane Applications. We offer standard products and customized solutions.
-
KVTS -
Knopp Incorporated
The Knopp Voltage Transformer Testing System is designed to measure the accuracy of instrument transformers having 120 volt secondaries and up to 14,400 volt primaries (special order for up to 36,000 volt primaries is available). The system includes a control console which contains the control circuitry, ANSI standard burdens, and the Knopp Automatic Transformer Comparator. The Knopp precision and loading transformer set is also included (as pictured) and is connected to the console via a special cable.
-
KVTS -
The Eastern Specialty Company
The Knopp Voltage Transformer Testing System is designed to measure the accuracy of instrument transformers having 120 volt secondaries and up to 14,400 volt primaries (special order for up to 36,000 volt primaries is available). The system includes a control console which contains the control circuitry, ANSI standard burdens, and the Knopp Automatic Transformer Comparator. The Knopp precision and loading transformer set is also included (as pictured) and is connected to the console via a special cable.
-
PTTS Series -
Shanghai Jiuzhi Electric Co., Ltd.
PTTS series power transformer test system is the complete test system for single and three phase power transformer and power reactor up to 765kV. The system will perform the following tests in accordance with ANSI / IEEE C57.12.90 and IEC 76 latest edition standards.
-
Instrument Transformers Ltd.
Designing & manufacturing a range of high quality, voltage transformers in three different frame sizes for both measuring and protection duties. Transformers which are designed to comply with the requirements of IEC 61869-3 or other international standards as required can be supplied to satisfy most Low Voltage applications.
-
NEO TELE-TRONIX PVT. LTD
Fully equipped with latest machines and tools, we are a prominent manufacturer and exporter of Transformer Winding Resistance Meter. The meter is used in electrical, power generation and engineering sector for testing transformers. Available in different models, this testing equipment is in strict tandem with industry standards. We use best grade raw materials to manufacture this Transformer Winding Resistance Meter. We offer this resistance meter to clients at economical price.
-
DT Series -
Shimadzu Corp.
ISO Class 1 Compliant Differential Transformer Type Extensometers The ISO 6892-1 standard for tensile testing of metallic materials prescribes Class 1 or higher extensometers, and JIS Z2241 prescribes Class 2 or higher extensometers when measuring withstanding pressure. The DT series includes Class 1 compliant differential transformer type extensometers, which can be used to implement test methods compliant with metal tensile test standards.
-
WABC -
Wuhan Sangao Electrical Test Installations Limit Co.
Acc to IEC and Relevant national standard, In the power transformer production, transfer and user test process, Transformer ratio test is necessary project, This can be used for quality supervision of transformer factory and the use process, prevent the transformer winding inter turn short circuit, open circuit, connection error, pressure regulating switch failure or contact fault.So our company development and production of automatic ratio tester in the original basis according to the user's site using requirements , make the operation more convenient, complete function, stable and reliable data, the testing speed is greatly improved.To meet the needs of all kinds of small medium and large transformer ratio test.